Reentrant connectors allow standard coaxial cable to be used as high voltage
charging lines, transmission lines between a pulsed power source and load, or
Pulse Forming Lines (PFL's).
These connectors consist of a two-component plug assembly and mating jack. The
maximum continuous or pulsed operating conditions are determined by the cable itself.
Please consult the cable manufacturer for detailed specifications and recommendations.
The outer insulation and braided shield are stripped leaving a length of center
conductor that passes completely through the connector. The prepared end of the
cable is inserted through the threaded component of the plug and the sleeve is
then soldered to a short length of exposed braid. Therefore the shield of the cable
must always be at ground potential. Instructions for cable preparation and all parts
required for installation are provided with each connector.
The HN-58 connector is designed for panel mounting and power supply applications.
The hv terminal within the insulating tube is spring loaded thereby insuring secure
contact with the center conductor of the coaxial cable. A 60-cm length of hv wire then
connects to the user's circuit.
HN-68, -70, -78, -88 and -89 connectors are designed for capacitor charging or pulse transmission
and the center conductor is attached to the user's apparatus using the most convenient means,
such as direct soldering, Multi-Contact
plug-socket sets, etc. These connectors are solid brass with nickel or silver plating as
applicable. The plug and jack both employ O-ring seals so these connectors may be used with
pressurized systems (e.g., Marx generators) or experimental
chambers at modest vacuum.
Additional technical
information and an installation guide may be obtained by clicking on the model number in the
following table.
Reentrant Connectors
| Model |
Typical Applications |
Cable Types |
Max. DC Voltage, kV |
Max. Pulsed Voltage, kV |
Maximum Pressure, kPa (psig) |
Dielectric Compatibility |
|---|
|
HN-58 |
HV power supplies Capacitor charging |
RG-8/U RG-213/U |
40 40 |
30 30 |
N/A |
Air or SF6 |
|
HN-68 |
Capacitor charging Low-current pulse lines |
RG-217/U |
70 |
120 |
410 (60) |
Air, SF6 or Oil |
|
HN-70 |
Capacitor charging Low-current pulse lines |
DS-2196 DS-2121 |
125 150 |
100 120 |
410 (60) |
Air, SF6 or Oil |
|
HN-78 |
mini-Marx generators (e.g., 60 ns, 10 kA) |
RG-218/U |
100 |
500 |
410 (60) |
Air, SF6 or Oil |
|
HN-88 |
Large charge-transfer pulse lines (to 80 kA) |
DS-2248 |
100 |
100 |
410 (60) |
Air, SF6 or Oil |
|
HN-89 |
mini-Marx generators (e.g., 60 ns, 10 kA) |
DS-2134 |
200 |
400 |
410 (60) |
Air, SF6 or Oil |
DS denotes Dielectric Sciences, Inc. (Chelmsford, Massachussets USA)
Model HN-58 connector assembly
Model HN-78 components
Pricing for standard connectors may be obtained from the links given on our
Sales page. Specifications are subject to change without notice.
Inquiries for additional product information are welcome!
Last revision: 20 August 2007